10 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 33 PPRREEPPAARRIINNGG TTHHEE LLOOCCAATTIIOONN 3.1 Physical Location It is
11 New Brunswick Operating manual 3.4 Space Requirements Allow at least four inches (10 cm) around the shaker for proper ventilation and for acc
12 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 1. Carefully remove the five screws on the underside of the plastic window co
13 New Brunswick Operating manual 44 IINNSSTTAALLLLAATTIIOONN CRUSH WARNING! Do not attempt to lift the Innova 43/43R by hand. Always u
14 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 3. Place a level on the top of the shaker. If necessary, make further adjust
15 New Brunswick Operating manual 55 FFEEAATTUURREESS 5.1 Controls Figure 3: Front Panel (detail) 1 Shaking Start/Stop switch 3 RS-232 port
16 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 5.2 LCD Display When the shaker is powered up, using the Power Switch locat
17 New Brunswick Operating manual Table 1: Screens Screen Name Meaning Features/Modes DISP Display Shows two user-selectable parameters* and
18 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual Table 3: Display Icons Icon Explanation This icon appears when audible
19 New Brunswick Operating manual Table 4: Alarms Indication Description TEMP The temperature deviates more than 1ºC from setpoint after achi
2 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual COPYRIGHT: Copyright © 2013 Eppendorf AG, Hamburg. No part of this publication
20 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 5.8 Software Interfaces The RS-232 port is next to the Power Switch on the ri
21 New Brunswick Operating manual When the shaker is powered up, there is a four-minute time delay prior to compressor start-up. 5.12 Service
22 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 66 GGEETTTTIINNGG SSTTAARRTTEEDD 6.1 Platform Assemblies The Innova 43/43R
23 New Brunswick Operating manual Clamps for 2-, 2.8-, 4- and 6-liter flasks are shipped with an additional girdle to keep the flasks in place (s
24 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual Connect the power cord to the power connector, then connect the other end to a
25 New Brunswick Operating manual Figure 8: Gas Monitor (optional) Figure 9: Gas Fitting (with optional Gas Manifold) 1 Gas manifold conn
26 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 6.6 Optional Germicidal UV Lamp WARNING! Never try to operate
27 New Brunswick Operating manual The recommended operating temperature when using this option is 15 - 37ºC; the maximum operating temperature is
28 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual Figure 12a: Humidity Monitor (optional) 1 Humidity monitor When the h
29 New Brunswick Operating manual Figure 12c: RH Sensor Connection M1282-7002 1 Board inside the service compartment Figure 12d: Humidity Se
3 New Brunswick Operating manual CAUTION! This equipment must be operated as described in this manual. If operational guidelines are n
30 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 1. Open the lid and temporarily remove the platform. 2. Make sure that the d
31 New Brunswick Operating manual 77 OOPPEERRAATTIIOONN 7.1 Safety Precautions Before operating the shaker, verify that anyone involved wit
32 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 7.3 Starting the Shaker To initially start the shaker, close the lid and tur
33 New Brunswick Operating manual Figure 13: Changing Display Parameter ºC 23 RPM 120 DISP We 13:44
34 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual To modify a setpoint in this screen: 1. Use the Control Knob to highlight th
35 New Brunswick Operating manual 7.4.2 Summary Screen In this screen (see Figure 16), you can see both the current ACTUAL readings and the SETp
36 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual To move out of this screen and into the next: 1. Use the Control Knob to hig
37 New Brunswick Operating manual To change the time (Hour/Min): 1. Turn the knob to highlight the time (16:19 in the sample screen above), the
38 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual On means the light is always on, and Off means the light is always off, unless
39 New Brunswick Operating manual 2. Turn the Knob to the right until the next screen, RS232 (COMM), appears. If you turn too far and enter ano
4 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual TABLE OF CONTENTS 1 OVERVIEW ...
40 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual Table 5: Communication Mode Mode Application Off The RS-232 port is not op
41 New Brunswick Operating manual Figure 20: Calibrate Screen CALIBRATE °C Offset : 0.
42 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 7.5 Programming the Shaker 7.5.1 Timer Only By setting an HRS setpoint in th
43 New Brunswick Operating manual 2. Turn the Knob until the field says New. Click the Knob in to select this mode. The screen for Program 1 -
44 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 7. Turn the Knob to highlight the RPM setting (Off in the sample screen above
45 New Brunswick Operating manual Whatever step is shown on the right-hand side of the display is settable (in Figure 23, it is Step 2). To scro
46 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 7.5.4 Editing a Program Use the Edit function to open a program you have al
47 New Brunswick Operating manual 7.7 Temperature Offset Calibration The temperature probe and the temperature controller are calibrated toget
48 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 5. When the Temperature Offset is set to any value other than 0, the icon w
49 New Brunswick Operating manual 7.9 Power Interruption In the event of a power failure, the Innova 43/43R Shakers are equipped with an autom
5 New Brunswick Operating manual 6.9 FILLING THE WATER RESERVOIR ...
50 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 88 MMAAIINNTTEENNAANNCCEE WARNING! When cleaning the shaker,
51 New Brunswick Operating manual Spills involving fresh cultures or samples known to have low concentrations of biomass should be flooded with d
52 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 99 SSEERRVVIICCEE && AACCCCEESSSSOORRIIEESS 9.1 Troubleshooting
53 New Brunswick Operating manual Symptom(s) Probable Cause(s) & Solution(s) Shaker does not run at set speed. Shaker is running in Progr
54 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual Symptom(s) Probable Cause(s) & Solution(s) Photosynthetic GRO lamp
55 New Brunswick Operating manual 9.3 Opening the Service Compartment WARNING! Before opening the Service Compartment, always turn o
56 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual Figure 26: Fuse Replacement 1 Fuses (F1-F4) 2 Service Compartment 9.5
57 New Brunswick Operating manual Be sure to follow all the WARNINGS and the NOTE above as well as the procedure outlined below when you replace
58 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 3. Remove the two thumbscrews from the diffuser holder. Figure 28: Replacin
59 New Brunswick Operating manual In the event the lid does not stay in the fully open position, you may want to adjust the lid tension: tighten
6 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 9.11.2 Flask Clamps for Platforms ...
60 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 5. Wearing plastic gloves, remove the germicidal lamp by pressing it toward t
61 New Brunswick Operating manual Figure 30: Drive Assembly 1 Spill deflector 2 Drive assembly 3 Bearing housing To replace the drive be
62 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual Figure 31: Belt Replacement & Adjustment 1 Drive belt 4 Four motor
63 New Brunswick Operating manual 9.10 Replacement Parts In Table 7 below you will find commonly needed replacement parts for your Innova 43/4
64 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual Description Part No. 500 mL Erlenmeyer flask Dedicated Platform M1191-9911 1
65 New Brunswick Operating manual Clamp Size Part Number 2.8 L Fernbach Flask ACFE-2800S 4 L Erlenmeyer Flask ACE-4000S 5 L Erlenmeyer Flas
66 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 9.11.5 Optional Gas Manifold Kit Table 12: Gas Manifold Kit (Factory-Insta
67 New Brunswick Operating manual Figure 32: Utility Basket (optional) 9.11.10 Optional Remote Alarm The Innova 43/43R can be equipped wit
68 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 1100 DDRRAAWWIINNGGSS,, GGRRAAPPHHSS && TTAABBLLEESS 10.1 Schemat
69 New Brunswick Operating manual Figure 33b: Control Schematics (right side) POWER DISTRIBUTIONBOARDM1282-7011POWER SUPPLYCONTROL BOARDM1282-7
7 New Brunswick Operating manual 11 OOVVEERRVVIIEEWW The Innova 43/43R Incubator Shakers are large-capacity orbital shakers that utilize an
70 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual Figure 34: Refrigeration Schematic 10.2 Load & Speed Graphs The fol
71 New Brunswick Operating manual Figure 35: Load & Speed for 1-Inch Orbit Shakers (20% Full) 050100150200250300350400450500<20 20 to 30
72 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 1111 SSPPEECCIIFFIICCAATTIIOONNSS These specifications assume a maximum loa
73 New Brunswick Operating manual Innova 43 & 43R Incubator Shaker CHAMBER DIMENSIONS 24 inches deep X 34.5 inches wide X 19 inches high from
74 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 11.1.1 CE Declaration of Conformity
75 New Brunswick Operating manual 1122 AAPPPPEENNDDIIXX:: RREEMMOOTTEE PPRROOGGRRAAMMMMIINNGG 12.1 Setting Up with HyperTerminal You can
76 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 12.2 Overview of Command Sets Using an optional RS-232 interface, the user h
77 New Brunswick Operating manual an optional line feed control character may also be included but must follow the carriage return character. Wh
78 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 12.4 Set Commands Code Meaning Format CL Command Grow Lamp CL<Space>&
79 New Brunswick Operating manual Code Meaning Format PR Read Profile step in memory PR<Space><Arg1><Space><Arg2><
8 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual To accommodate customer needs, a wide variety of platforms can be used with the
80 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 12.6 Report Request Commands Code Meaning Format RI Report Software Versio
81 New Brunswick Operating manual 12.7 Set/Get Date & Time Code Meaning Format =D ?D Set Date & Time Get Date & Time =D<Spa
82 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual 1133 IINNDDEEXX A Accessories, 63 Racks & Trays, 65 Actual Tempera
83 New Brunswick Operating manual Flask Clamps, 64 Installation of, 22 Front View, 11 Fuses, 55 G Gas Manifold Kit, 24, 66 Germicidal Lamp, 66 Gl
84 Innova 43 & 43R Incubator Shakers M1320-0050 Operating manual Resetting the Time, 37 Returned Material Authorization Number, 54 Returned Mat
85 New Brunswick Operating manual
Evaluate your manualGive us your feedback.www.eppendorf.com/manualfeedbackYour local distributor: www.eppendorf.com/worldwide Eppendorf AG · Hamburg ·
9 New Brunswick Operating manual 22 IINNSSPPEECCTTIIOONN && UUNNPPAACCKKIINNGG OOFF EEQQUUIIPPMMEENNTT 2.1 Inspection of Boxes Af
Kommentare zu diesen Handbüchern